Blood Cell Counter Countender 80+    

 

SFRI COUNTENDER 80+ is a five part differential blood cell counter designed for the most demanding clinical laboratories. SFRI Countender 80+ provides the most accurate and consistent results on the market using a laser scatter technology enabling the optimum Differentiation of blood cells.

SFRI COUNTENDER 80 + addresses the most demanding lab expectations regarding :

  • Results accuracy
  • Results repetibility
  • Working through put (80 tests per hour)
  • Instrument handling : COUNTENDER 80 + is really very easy to use and very user friendly
  • Design : SFRI continuously pays attention to its design instrument range,

COUNTENDER 80 + is already a must for all mid size labs !!

 
Technology
 
  • Impedance for WBC, RBC & Plts counting and sizing
  • LASER flow cytometry for WBC differentiation
  • Optical absorbance for haemoglobin
Parameters
 
  • WBC, lym %&#, Mon %&#, Neutro %&#, Eosino %&#, Baso %&#.
  • RBC, HGB, HCT, MCV, MCH, MCHC, RDW, PLTS, MPV, PCT, PDW
    Accuracy Linearity
 
WBC
< 1.5% @ 8,000/µL 0.1 to 99.9  103/µL          ±0.2 or ±2%
 
RBC
< 1.0% @ 5,000,000/µL 0.02 to 9.99  106/µL        ±0.05 or ±2%
 
HGB
< 1.0% @ 8,000/µL 0.0 to 30  g/dl                ±0.2 or ±2%
 
MCV
< 1.0% @ 90 fL 40 to 150  fL                   ±0.2 or ±2%
 
PLTS
< 3.0% @ 250,000/µL 10 to 1000  103/µL           ±10 or ±5%
Throughput
  80 tests per hour manual mode
Workstation
 
  • Microsoft Windows XP
  • Monitor
  • Keyboard, mouse, lightpen
  • Optional bar code reader
  • Two RS 232 serial ports and one parallel printer port
Reagents
 
  • all reagents are coded (codes to be inserted manually or via bar code reader)
  Type Packing    
  Diluent 20 L    
  Leucoprotective sheath 10 L    
  Lyse 0.5 L    
  Enzymatic cleaner 10 L    
  Controls 3 levels Low, Normal, High    
Samples volumes
  Direct mode 180 µl    
  Auto sampler 180 µl    
  Sample saver 80 µl    
Software
  Patient identification PID 12 digits, name, first name, sex, Date of Birth, comments
Large Storage Capacity
 
  • User selectable report format
  • Automatic or manual calibration
  • Selectable units / MKS, SI, SI modified
  Patient data storage 100 000 results with scatter grams and histograms
  Patient normal range 8 sets, user modified
  Patient action limits user defined
Multi language capability
Quality Control
 
  • assay files : 12 lots, 3 levels each
  • Printed log of QC data with automatic calculation of mean, SD, CV
  • Monthly Levey Jennings plot of QC data, X-B, Bull’s moving average, Westgard rules
  • Diagnostic alerts to assist operator
  • Maintenance log
  • Errors log
Operating conditions
  Temperature
15°- 32 ° C
  Humidity 10 – 90 %
  Voltage 90-250 VAC, 47-63 Hertz